Capacitive displacement sensors from Micro-Epsilon are available in different designs and versions. The sensors are differentiated by their measuring range, their design and by the technology used to manufacture them. The capacitive sensors are available in a cylindrical design (with integrated cable or socket) or as flat sensors (with integrated cable). The displacement sensors can be exchanged without recalibration; the sensor replacement is therefore complete in rapid time. The majority of sensors can be used in clean rooms; use in ultra high vacuums is also possible.
Click on the respective category to obtain further information about capacitive sensors.
Cylindrical sensors with female connector
Cylindrical sensors with female connector
Model
Measuring range
Min. ø Target
Dimension
CS005
0,05 mm
3 mm
Ø6 × 12 mm
CS02
0,2 mm
5 mm
Ø6 × 12 mm
CS05
0,5 mm
7 mm
Ø8 × 12 mm
CS08
0,8 mm
9 mm
Ø10 × 15 mm
CS1
1 mm
9 mm
Ø10 × 21 mm
CS1HP
1 mm
9 mm
Ø10 × 20 mm
CS2
2 mm
17 mm
Ø20 × 24 mm
CS3
3 mm
27 mm
Ø30 × 24 mm
CS5
5 mm
37 mm
Ø40 × 24 mm
CS10
10 mm
57 mm
Ø60 × 24 mm
CS005 sensors can't be used with the controller capaNCDT6019 and capaNCDT6100.
Detail
Please move your mouse over the table to show more detailed information.
CS005
Weight:
2 g
Resolution:
±0,0375 nm *
Linearity:
±0,2 % F.S.O. *
Temperature stability sensitivity:
11 ppm/°C
Operation temperature max.:
+200 °C
* depends on controller unit
CS02
Weight:
2 g
Resolution:
±0,15 nm *
Linearity:
±0,2 % F.S.O. *
Temperature stability sensitivity:
11 ppm/°C
Operation temperature max.:
+200 °C
* depends on controller unit
CS05
Weight:
4 g
Resolution:
±0,375 nm *
Linearity:
±0,05 % F.S.O. *
Temperature stability sensitivity:
11 ppm/°C
Operation temperature max.:
+200 °C
* depends on controller unit
CS08
Weight:
7 g
Resolution:
±0,6 nm *
Linearity:
±0,05 % F.S.O. *
Temperature stability sensitivity:
11 ppm/°C
Operation temperature max.:
+200 °C
* depends on controller unit
CS1
Weight:
8 g
Resolution:
±0,75 nm *
Linearity:
±0,05 % F.S.O. *
Temperature stability sensitivity:
30 ppm/°C
Operation temperature max.:
+200 °C
* depends on controller unit
CS1HP
Weight:
8 g
Resolution:
±0,75 nm *
Linearity:
±0,05 % F.S.O. *
Temperature stability sensitivity:
11 ppm/°C
Operation temperature max.:
+200 °C
* depends on controller unit
CS2
Weight:
50 g
Resolution:
±1,5 nm *
Linearity:
±0,05 % F.S.O. *
Temperature stability sensitivity:
30 ppm/°C
Operation temperature max.:
+200 °C
* depends on controller unit
CS3
Weight:
70 g
Resolution:
±2,25 nm *
Linearity:
±0,05 % F.S.O. *
Temperature stability sensitivity:
30 ppm/°C
Operation temperature max.:
+200 °C
* depends on controller unit
CS5
Weight:
95 g
Resolution:
±3,75 nm *
Linearity:
±0,05 % F.S.O. *
Temperature stability sensitivity:
30 ppm/°C
Operation temperature max.:
+200 °C
* depends on controller unit
CS10
Weight:
180 g
Resolution:
±7,5 nm *
Linearity:
±0,05 % F.S.O. *
Temperature stability sensitivity:
30 ppm/°C
Operation temperature max.:
+200 °C
* depends on controller unit
Cylindrical sensors with integrated cable
Cylindrical sensors with integrated cable
Model
Measuring range
Min. ø Target
Dimension
CSH02-CAm1,4
0,2 mm
7 mm
Ø8 × 14 mm
CSH05-CAm1,4
0,5 mm
7 mm
Ø8 × 14 mm
CSH1-CAm1,4
1 mm
11 mm
Ø12 × 14 mm
CSH1,2-CAm1,4
1,2 mm
11 mm
Ø12 × 14 mm
Sensors with integrated cable can't be used with the controller capaNCDt6019.
Detail
Please move your mouse over the table to show more detailed information.
CSH02-CAm1,4
Weight:
30 g
Resolution:
±0,15 nm *
Linearity:
±0,05 % F.S.O. *
Temperature stability sensitivity:
-12 ppm/°C
Operation temperature max.:
+200 °C
Cable length:
1,4 m
* depends on controller unit
CSH05-CAm1,4
Weight:
30 g
Resolution:
±0,38 nm *
Linearity:
±0,05 % F.S.O. *
Temperature stability sensitivity:
-12 ppm/°C
Operation temperature max.:
+200 °C
Cable length:
1,4 m
* depends on controller unit
CSH1-CAm1,4
Weight:
33 g
Resolution:
±0,75 nm *
Linearity:
±0,05 % F.S.O. *
Temperature stability sensitivity:
-12 ppm/°C
Operation temperature max.:
+200 °C
Cable length:
1,4 m
* depends on controller unit
CSH1,2-CAm1,4
Weight:
33 g
Resolution:
±0,9 nm *
Linearity:
±0,05 % F.S.O. *
Temperature stability sensitivity:
-12 ppm/°C
Operation temperature max.:
+200 °C
Cable length:
1,4 m
* depends on controller unit
Flat sensors with integrated cable
Flat sensors with integrated cable
Model
Measuring range
Min. ø Target
Dimension
CSH02FL-CRm1,4
0,2 mm
7 mm
10,5 × 8 × 4 mm
CSH05FL-CRm1,4
0,5 mm
7 mm
10,5 × 8 × 4 mm
CSH1FL-CRm1,4
1 mm
11 mm
17 × 12 × 4 mm
CSH1,2FL-CRm1,4
1,2 mm
11 mm
17 × 12 × 4 mm
Sensors with integrated cable can't be used with the controller capaNCDT 6019.
Detail